=======Simchair MKIV cyclic / pedals sensitivity (rates) control panel======= | =======Simchair MKIV cyclic / pedals sensitivity (rates) control panel======= | ||
+ | |||
+ | {{http:// | ||
====Summary==== | ====Summary==== | ||
- | This panel allows you to precisely | + | This panel allows you to set the sensitivity (rates) of your cyclic and pedals |
- | Default | + | The default |
MARK SENS | MARK SENS | ||
Line 23: | Line 25: | ||
* 2 x 16K1 linear 10K pots | * 2 x 16K1 linear 10K pots | ||
* 2 x M3 nuts | * 2 x M3 nuts | ||
- | * 1 x ethernet | + | * 1 x Ethernet |
* 4 x M3x12 screws | * 4 x M3x12 screws | ||
- | * 2 x M3x30 screws | + | * 2 x M3x40 screws |
==== Repository path ==== | ==== Repository path ==== | ||
- | V: | + | simchair4_models\printable components\peripherals\helicopter\cyclic lever\d_sens_control_panel - models |
==== Assembly Guide ==== | ==== Assembly Guide ==== | ||
- | Wire pots in the following way: | + | Wire the pots as described below and fix the cable with some hot glue: |
+ | |||
+ | {{: | ||
ETHERNET WHITE-ORANGE -> POT 1 & 2 VCC | ETHERNET WHITE-ORANGE -> POT 1 & 2 VCC | ||
Line 39: | Line 43: | ||
ETHERNET BLUE -> POT 2 SIGNAL | ETHERNET BLUE -> POT 2 SIGNAL | ||
| | ||
- | This panel connects to the RATES port on the cyclic base. The port is wired in the following way: | + | |
+ | This panel connects to the RATES (FORMER FTCR) port, located | ||
SOCKET PIN 1 -> VCC | SOCKET PIN 1 -> VCC |