User Tools

Site Tools


simchair4:guide_sens_control_panel

This is an old revision of the document!


Simchair MKIV cyclic / pedals sensitivity (rates) control panel

Summary

This panel allows you to precisely set sensitivity (rates) of your cyclic and pedals in a linear way. Adjust knobs until your physical stick movements will roughly correspond those of the on-screen one, or in the way you find comfortable.

Default sensitivity values set in software, from bottom-left mark:

MARK   SENS
1      80
2      85
3      90
4      95
5      100 (MARKED WHITE)
6      105
7      110
8      115
9      120
10     125

Components

  • 2 x 16K1 linear 10K pots
  • 2 x M3 nuts
  • 1 x ethernet cable
  • 4 x M3x12 screws
  • 2 x M3x30 screws

Repository path

V:\simchair4\simchair4_models\printable components\peripherals\helicopter\cyclic lever\d_sens_control_panel - models

Assembly Guide

Wire pots in the following way:

ETHERNET WHITE-ORANGE -> POT 1 & 2 VCC
ETHERNET ORANGE       -> POT 1 & 2 GND
ETHERNET WHITE-GREEN  -> POT 1 SIGNAL
ETHERNET BLUE         -> POT 2 SIGNAL

This panel connects to the RATES (FORMER FTCR) port on the cyclic base. The port is wired in the following way:

SOCKET PIN 1 -> VCC
SOCKET PIN 2 -> GND
SOCKET PIN 3 -> ADS1115 A2
SOCKET PIN 4 -> ADS1115 A3
simchair4/guide_sens_control_panel.1569355061.txt.gz · Last modified: 2019/09/24 21:57 by hc625ma